The Add Event setting page and the Add Schedule setting page are basically the same
except that the Add Schedule setting page does not have the option “Trigger by” to
indicate the sources of the trigger event.
Click Save to save and activate your settings when you complete setting.
Delete: delete the event cluster setting.
Modify: modify the event cluster setting.
Application Setting > Event > Trigger (manual test of trigger
response)
Whenever the camera detects abnormal events during the scheduled time, it will
automatically respond by performing trigger response. There are 3 types of trigger
responses: alarm sending, LED status indicator flash, and emailing the alarm or
recorded image to the specified server. To use this function, enter the server
information by accessing Application Setting > Event > Event Server. You may
perform manual test as specified in this section once you complete the setting to
ensure that all functions are working properly.
Trigger setting
The default status of the digital input pin is set as “Normal Open”, but users can
change it to “Normal grounded” by setting the page
“Setting->Application->Event->Trigger”:
1. When alarm input is set to be “Normal Open”, then the external device connected
to alarm input pin should be in open status. So when the external device is
triggered to close status, the alarm input pin will be triggered.
2. On the contrary, when alarm input pin is set to be “Normal Grounded”(see the
figure below), then the external device connected to alarm input pin should be in
63
Komentarze do niniejszej Instrukcji